Dual Laser Acousto-Optical Diffraction Technique for the Calibration of a CO2 Laser Scattering Apparatus
LY CHANG,L ZENG,JX CAO,CX YU,QX ZU
DOI: https://doi.org/10.1063/1.1141356
IF: 1.6
1990-01-01
Review of Scientific Instruments
Abstract:In this paper a dual laser acousto-optical diffraction technique is described that provides an absolute calibration of a CO2 laser coherent scattering apparatus and other heterodyne receivers. Rather than directly detecting the sound pressure of the acoustic field or the power diffracted from the CO2 laser beam, the sound pressure is measured with the heterodyne detection of acousto-optical diffraction from a He-Ne laser beam. Noise equivalent power (NEP) measurement of the heterodyne receiver for the CO2 laser scattering apparatus and the studies of the detector bias and local oscillator power dependence of NEP values are performed by this technique. The measured minimum NEP value (6.8×10−20 W/Hz) is very close to the quantum noise limit.
What problem does this paper attempt to address?