Foil Deposition Alpha Collector Probe for TFTR’s D-T Phase

HW HERRMANN,DS DARROW,JR TIMBERLAKE,SJ ZWEBEN,GP CHONG,CS PITCHER,RG MACAULAYNEWCOMBE
DOI: https://doi.org/10.1063/1.1146539
IF: 1.6
1995-01-01
Review of Scientific Instruments
Abstract:A new foil deposition alpha collector sample probe has been developed for TFTR’s D-T phase. D-T fusion produced alpha particles escaping from the plasma are implanted in nickel foils located in a series of collimating ports on the detector. The nickel foils are removed from the tokamak after exposure to one or more plasma discharges and analyzed for helium content. This detector is intended to provide improved alpha particle energy resolution and pitch angle coverage over existing lost alpha detectors, and to provide an absolutely calibrated cross-check with these detectors. The ability to resolve between separate energy components of alpha particle loss is estimated to be ∼20%. A full 360° of pitch angle coverage is provided for by eight channels having an acceptance range of ∼53° per channel. These detectors will be useful in characterizing classical and anomalous alpha losses and any collective alpha instabilities that may be excited during the D-T campaign of TFTR.
What problem does this paper attempt to address?