Magnetic field error in twin depolarized interferometric fiber optic gyroscopes induced by vertical magnetic field

hui tian,lei chen,yuxiang zhao,dengwei zhang,xiaowu shu,cheng liu,shuangliang che
DOI: https://doi.org/10.1016/j.yofte.2014.11.006
IF: 2.8
2015-01-01
Optical Fiber Technology
Abstract:•An error will be induced in TD-IFOGs in the axial magnetic field.•The error comes from the fiber’s bending.•As to a TD-IFOG manufactured, the error is linear to the axial magnetic field.
What problem does this paper attempt to address?