Case Study of Applying Active Noise Control on Communication Chassis

Haishan Zou,Di Yu,Xiaojun Qiu
DOI: https://doi.org/10.1121/1.4709093
2012-01-01
Abstract:In some communication chassis, running of the cooling fan causes the noise emission level of the chassis exceed the upper limited level of the standards and regulations. In this case study, various sound transmission paths are indentified, such as the structure borne sound transmission, the air intake and the air outtake, etc. To reduce the direct noise, a metal enclosure which divided into several ducts and with new intake and outtake on its surface is used to cover the chassis. The wall of ducts is equipped with absorbing material to form mufflers, so the middle and high frequency noise is reduced successfully. The key point is that the active control systems are installed in the ducts to reduce the low frequency noise. A noise level reduction of 6-8 dB is achieved with this active-passive hybrid method. However, it is found that it is impossible to achieve such a reduction level without using active noise control because of the abundant low frequency component of the noise.