Asymmetrical In-Fiber Mach-Zehnder Interferometer for Curvature Measurement.

Bing Sun,Yijian Huang,Shen Liu,Chao Wang,Jun He,Changrui Liao,Guolu Yin,Jing Zhao,Yinjie Liu,Jian Tang,Jiangtao Zhou,Yiping Wang
DOI: https://doi.org/10.1364/oe.23.014596
IF: 3.8
2015-01-01
Optics Express
Abstract:We demonstrated a compact and highly-sensitive curvature sensor based on a Mach-Zehnder interferometer created in a photonic crystal fiber. Such a Mach-Zehnder interferometer consisted of a peanut-like section and an abrupt taper achieved by use of an optimized electrical arc discharge technique, where only one dominating cladding mode was excited and interfered with the fundamental mode. The unique structure exhibited a high curvature sensitivity of 50.5 nm/m-1 within a range from 0 to 2.8 m-1, which made it suitable for high-sensitivity curvature sensing in harsh environments. Moreover, it also exhibited a temperature sensitivity of 11.7 pm/°C.
What problem does this paper attempt to address?