Fast 3D Imaging in Optical Microscopy

Hsi-Hsun Chen,Xiaomin Zhai,Wei Tang Lin,Yuan Luo
DOI: https://doi.org/10.1117/2.1201501.005670
2015-01-01
SPIE Newsroom
Abstract:Optical microscopy approaches that provide acquisition of 3D information from a volumetric object are attractive for a number of biomedical applications. For example, conventional widefield microscopy requires depth focusing to obtain 3D signals within a biological sample volume. With confocal scanning microscopy,1 micrometer—or sub-micrometer—level resolution can be achieved, and contrast can be improved by using a small aperture to reject out-of-focus light. Efforts to improve the scanning speeds of these techniques, by optimizing scanning algorithms,2, 3 are ongoing. Such methods, however, are complicated and do not eliminate the need for moving parts. In addition, the complex designs that are involved increase the cost of the devices and reduce their robustness. Digital holographic microscopy (DHM)4 has recently been used to retrieve 3D information for biological samples. With DHM, a high-resolution CCD camera is used to record holograms. Each hologram consists of a 2D slice of the object, and the holograms are superimposed and stored in computer memory. Although with this approach volumetric image data for an object can be reconstructed from the stored information, it requires complex computational reconstruction techniques and has stringent optical and mechanical design requirements for imaging. We have developed a spatial-spectral imaging method that can be used to acquire resolved images from multiple depths simultaneously. We are able to leverage a strong Bragg filtering property of a wavefront—with respect to angle (spatial) and wavelength (spectral)5—in our volume holographic imaging (VHI) approach to capture multi-plane images in real time, without scanning. Furthermore, a key volume hologram component in VHI offers a 3D pupil, rather than a conventional 2D diffractive element. By incorporating VHI with different recording strategies, we have engineered this functionally unique 3D pupil Figure 1. (a) Schematic illustration of a volume holographic imaging (VHI) experimental setup, which includes two phase-coded multiplexed gratings. (b) Schematic diagram that illustrates the functional recording method for a spatial filter-encoded volume hologram (VH). An internal angle ( ) is introduced during multiplexing. fO : Focal length of the objective lens. fC : Focal length of the collector lens.
What problem does this paper attempt to address?