Highly Ordered Ni-Ti-O Nanotubes for Non-Enzymatic Glucose Detection

Ruiqiang Hang,Yanlian Liu,Ang Gao,Long Bai,Xiaobo Huang,Xiangyu Zhang,Naiming Lin,Bin Tang,Paul K. Chu
DOI: https://doi.org/10.1016/j.msec.2015.02.027
2015-01-01
Abstract:Anodization is used to fabricate Ni–Ti–O nanotube (NT) electrodes for non-enzymatic glucose detection. The morphology, microstructure and composition of the materials are characterized by field emission scanning electron microscopy (FE-SEM), high resolution transmission electron microscopy (HR-TEM) and X-ray photoelectron spectroscopy (XPS). Our results show amorphous and highly ordered NTs with diameter of 50 nm, length of 800 nm, and Ni/Ti ratio (at %) of 0.35 can be fabricated in ethylene glycol electrolyte supplemented with 0.2 wt.% NH4F and 0.5 vol.% H2O at 30 °C and 25 V for 1 h. Electrochemical experiments indicate that at an applied potential of 0.60 V vs. Ag/AgCl, the electrode exhibits a linear response window for glucose concentrations from 0.002 mM to 0.2 mM with a response time of 10 s, detection limit of 0.13 μM (S/N = 3), and sensitivity of 83 μA mM− 1 cm− 2. The excellent performance of the electrode is attributed to its large specific area and fast electron transfer between the NT walls. The good electrochemical performance of the Ni–Ti–O NTs as well as their simple and low-cost preparation method make the strategy promising in non-enzymatic glucose detection.
What problem does this paper attempt to address?