Motion of the femoral condyles in flexion and extension during a continuous lunge.

Yong Feng,Tsung-Yuan Tsai,Jing-Sheng Li,Shaobai Wang,Hai Hu,Changqing Zhang,Harry E Rubash,Guoan Li
DOI: https://doi.org/10.1002/jor.22826
2015-01-01
Abstract:Numerous studies have reported on in-vivo posterior femoral condyle translations during various activities of the knee. However, no data has been reported on the knee motion during a continuous flexion-extension cycle. Further, few studies have investigated the gender variations on the knee kinematics. This study quantitatively determined femoral condylar motion of 10 male and 10 female knees during a continuous weightbearing flexion-extension cycle using two-dimensional to three-dimensional fluoroscopic tracking technique. The knees were CT-scanned to create three-dimensional models of the tibia and femur. Continuous images of each subject were taken using a single-fluoroscopic imaging system. The knee kinematics were measured along the motion path using geometric center axis of the femur. The results indicated that statistical differences between the flexion and extension motions were only found in internal-external tibial rotation and lateral femoral condylar motion at the middle range of flexion angles. At low flexion angles, male knees have greater external tibial rotation and more posteriorly positioned medial femoral condyle than females. The knee did not show a specific pivoting type of rotation with flexion. Axial rotation center varied from lateral to medial compartments of the knee. These data could provide useful information for understanding physiological motion of normal knees.
What problem does this paper attempt to address?