A Simple Practical Technique to Protect the Side Branch During PCI for Coronary Bifurcation Lesions: Side Branch Balloon Submerged Embedding Technique

Yi Cheng,Yang,Dingguo Zhang,Zhijian Yang,Liansheng Wang
DOI: https://doi.org/10.1016/j.ijcard.2014.10.108
IF: 4.039
2015-01-01
International Journal of Cardiology
Abstract:Coronary bifurcations (CB) are frequently encountered and remain to be one of the most challenging lesion subsets for coronary intervention. The main strategy nowadays to treat CB lesions is the crossover technique. In brief, a stent was firstly implanted in the main vessel and then branch kissing balloon or the stent-angioplasty performed in the side branch according to the side branch stenosis [1Alegria-Barrero E. Foin N. Lindsay A.C. et al.How to optimize the percutaneous treatment of bifurcated lesions; dedicated stents vs. provisional stenting.Minerva Cardioangiol. 2013; 61: 575-590PubMed Google Scholar, 2Maeng M. Holm N.R. Erglis A. et al.Long-term results after simple versus complex stenting of coronary artery bifurcation lesions: Nordic Bifurcation Study 5-year follow-up results.J. Am. Coll. Cardiol. 2013; 62: 30-34Abstract Full Text Full Text PDF PubMed Scopus (137) Google Scholar]. However, the crossover technique is associated with high incidence of occlusion of the SB [[3]Kieehl S. Willeit J. The natural course of atherosclerosis. Part I: incidence and progression.Arterioscler. Thromb. Vasc. Biol. 1999; 19: 1484-1490Crossref PubMed Scopus (179) Google Scholar]. Therefore, protecting the SB is of great importance. The traditional strategy to protect the SB is preplacing a wire in it. The jailed wire can be served as a road map to the SB, which facilitates bailout treatment, thus reducing branch vessel remodeling in the case of acute occlusion of the side branch ostium [[4]Brunel P. Lefevre T. Darremont O. et al.Provisional T-stenting and kissing balloon in the treatment of coronary bifurcation lesions: results of the French multicenter “TULIPE” study.Catheter. Cardiovasc. Interv. 2006; 68: 67-73Crossref PubMed Scopus (92) Google Scholar]. However, in reality, the protection wire is often unable to prevent the SB from occlusion, and the exchange of the main vessel wire is very difficult while applying the SB remedial percutaneous transluminal coronary angioplasty (PTCA) if SB occlusion occurs. Furthermore, even if the wire comes into the side branch, it is hard for the balloon to reenter the SB. The increase of the operation time, contrast agent dosage and X-ray exposure time also adds to the patient's injuries.To overcome the previous problem, we designed a new technique for protecting the side branch: side branch balloon submerged embedding technique. Detailed steps are as follows: (1) both SB and the main vessel are wired and then the small-diameter balloon is advanced into the SB beforehand and makes sure that the proximal portion of the balloon protrudes into the main branch at a distance of 1–2 mm. (2) After the main vessel predialation and stent implantation, release the stent with minimum named pressure (8–10 atm). (3) Restudy angiogram, the submerged embedded balloon will be removed if the ostium of SB is not influenced and the wire positioned in the main vessel enters the side branch through meshes in the stent. The side-branch stent is then advanced at the distal part of the main vessel. After the regular postdialation of the main vessel, the operation is finished if the side branch is well blood-supplied. (4) PTCA of the side branch ostium is immediately performed when the side branch ostium stenosis is worsened. The wire positioned in the main branch will not be delivered into SB via meshes of stent until the stenosis of the ostium of the SB is improved and the blood flow comes back to balance well. The submerged embedded balloon inside the branch is then removed. The SB wire is delivered into the distal part of the main branch. Following this, the postdialation of the main branch stent is performed and the main branch–branch kissing balloon or the stent-angioplasty is performed in the side branch according to the degree of stenosis and blood flow of the SB ostium.Here we present one case of coronary heart disease, which performed this approach for side coronary bifurcations. The case was a 54-year-old woman with chest discomfort for one month. She has hypertension history for 20 years. Conventional coronary angiography demonstrated around 95% stenosis in proximal-segment of left anterior descending artery (LAD) and around 90% stenosis in proximal part of diagonal branch, respectively. No significant stenosis was found in LCX and RCA. The side branch balloon submerged embedding technique was used as described before. Runthrough wire was put into LAD and diagonal branch, respectively. A 1.5 mm ∗ 15 mm INVATEC balloon was advanced into the diagonal branch beforehand and made sure that the proximal portion of the balloon protrudes into the LAD at a distance of 1–2 mm. A 3.5 ∗ 21 mm sirolimus-eluting stent was implanted in LAD and released with a minimum named pressure (8 atm) for 2 s. No residual stenosis in LAD and no occlusion of the diagonal branch were found (Fig. 1). Patient improved, with no chest pain now.1. DiscussionThe branch balloon submerged embedding technique has the following advantages over the traditional side branch wire protection. (1) It can prevent the ostium of the side branch from aggravation. The predialation or stent implantation in the main vessel makes the plaque shift or change the kind of the stenosis, which leads to the ostium of the side branch occlusion or severe stenosis. As a result, the blood flow supplied to the side branch is reduced. The fact that the outer diameter of the submerged embedded balloon is much longer than the guide wire can partly protect the plaque against moving to the ostium of the side branch. The emergence of the technique offers considerable promise for the prevention of severe stenosis or occlusion in the ostium of the side branch and reduces the possibility of the implementation of the main branch-side branch kissing balloon or the stent-angioplasty in the side branch. (2) Performing PTCA with the aid of the submerged embedded balloon, we can restore the blood supply to the involved vessels, avoid artificial myocardial ischemia and myocardial necrosis, lower operation complications and decrease the pain that patients suffer. (3) It is favorable for exchanging the wires rapidly and reducing the difficulty of the balloon reentrance. The wire can find the ostium easily considering the fact that the dialationed side branch ostium has a long diameter and the resistance that the balloon comes into with is reduced significantly. As a result, the operation time and X-ray exposure time are both shortened and the contrast agent dosage is decreased. (4) The technique is simple to execute. The rate of protecting the wire and performing the operation is up to almost 100%. Branch balloon submerged embedding technique is an effective and safe measure to protect the SB during percutaneous coronary intervention (PCI) for bifurcation lesions.The difficult point of this technique is that it may get into trouble when removing the submerged embedded balloon. In our experience, the advance embedded balloon protrudes from the main branch slightly when the main branch predialation and stent implantation and the main branch are released with a minimum named pressure (6–8 atm). The balloon is opened up for a short while at a low pressure (4 atm) at where we come into resistance when removing comes into difficulty so as to create a fissure in the stent steel. The removed submerged embedded balloon will go on when the balloon is at negative pressure. The step will be repeated or the balloon pressure will be increased if the removed submerged embedded balloon is still not smooth. Deformation of the stent steel caused by the dilation of the submerged embedded balloon will be repaired by the postdialation of the balloon.A large collection of clinical practice experience shows that traditional wire protection technique can neither prevent the closure of side branches secondary to the plaque displacement nor restore blood flow to the involved side branch ostium. The difficulty of wire exchange and balloon reentrance will increase while the side branch is badly narrow, leading to aggravate suffering and prolong the operation time. In contrast, the branch balloon submerged embedding technique can protect the ostium of the side branch by means of preventing plaque from shifting and restore blood flow inside the shortest time. The technique reduces the difficulty of wire exchange and the dosage of contrast agent, and shortens the time of wire exchange and X-ray exposure. It is associated with low possibility of operation complications. More importantly, it does not increase the operation difficulty. This is why we decide to promote the technique, which is effective, safe and simple to execute. Coronary bifurcations (CB) are frequently encountered and remain to be one of the most challenging lesion subsets for coronary intervention. The main strategy nowadays to treat CB lesions is the crossover technique. In brief, a stent was firstly implanted in the main vessel and then branch kissing balloon or the stent-angioplasty performed in the side branch according to the side branch stenosis [1Alegria-Barrero E. Foin N. Lindsay A.C. et al.How to optimize the percutaneous treatment of bifurcated lesions; dedicated stents vs. provisional stenting.Minerva Cardioangiol. 2013; 61: 575-590PubMed Google Scholar, 2Maeng M. Holm N.R. Erglis A. et al.Long-term results after simple versus complex stenting of coronary artery bifurcation lesions: Nordic Bifurcation Study 5-year follow-up results.J. Am. Coll. Cardiol. 2013; 62: 30-34Abstract Full Text Full Text PDF PubMed Scopus (137) Google Scholar]. However, the crossover technique is associated with high incidence of occlusion of the SB [[3]Kieehl S. Willeit J. The natural course of atherosclerosis. Part I: incidence and progression.Arterioscler. Thromb. Vasc. Biol. 1999; 19: 1484-1490Crossref PubMed Scopus (179) Google Scholar]. Therefore, protecting the SB is of great importance. The traditional strategy to protect the SB is preplacing a wire in it. The jailed wire can be served as a road map to the SB, which facilitates bailout treatment, thus reducing branch vessel remodeling in the case of acute occlusion of the side branch ostium [[4]Brunel P. Lefevre T. Darremont O. et al.Provisional T-stenting and kissing balloon in the treatment of coronary bifurcation lesions: results of the French multicenter “TULIPE” study.Catheter. Cardiovasc. Interv. 2006; 68: 67-73Crossref PubMed Scopus (92) Google Scholar]. However, in reality, the protection wire is often unable to prevent the SB from occlusion, and the exchange of the main vessel wire is very difficult while applying the SB remedial percutaneous transluminal coronary angioplasty (PTCA) if SB occlusion occurs. Furthermore, even if the wire comes into the side branch, it is hard for the balloon to reenter the SB. The increase of the operation time, contrast agent dosage and X-ray exposure time also adds to the patient's injuries. To overcome the previous problem, we designed a new technique for protecting the side branch: side branch balloon submerged embedding technique. Detailed steps are as follows: (1) both SB and the main vessel are wired and then the small-diameter balloon is advanced into the SB beforehand and makes sure that the proximal portion of the balloon protrudes into the main branch at a distance of 1–2 mm. (2) After the main vessel predialation and stent implantation, release the stent with minimum named pressure (8–10 atm). (3) Restudy angiogram, the submerged embedded balloon will be removed if the ostium of SB is not influenced and the wire positioned in the main vessel enters the side branch through meshes in the stent. The side-branch stent is then advanced at the distal part of the main vessel. After the regular postdialation of the main vessel, the operation is finished if the side branch is well blood-supplied. (4) PTCA of the side branch ostium is immediately performed when the side branch ostium stenosis is worsened. The wire positioned in the main branch will not be delivered into SB via meshes of stent until the stenosis of the ostium of the SB is improved and the blood flow comes back to balance well. The submerged embedded balloon inside the branch is then removed. The SB wire is delivered into the distal part of the main branch. Following this, the postdialation of the main branch stent is performed and the main branch–branch kissing balloon or the stent-angioplasty is performed in the side branch according to the degree of stenosis and blood flow of the SB ostium. Here we present one case of coronary heart disease, which performed this approach for side coronary bifurcations. The case was a 54-year-old woman with chest discomfort for one month. She has hypertension history for 20 years. Conventional coronary angiography demonstrated around 95% stenosis in proximal-segment of left anterior descending artery (LAD) and around 90% stenosis in proximal part of diagonal branch, respectively. No significant stenosis was found in LCX and RCA. The side branch balloon submerged embedding technique was used as described before. Runthrough wire was put into LAD and diagonal branch, respectively. A 1.5 mm ∗ 15 mm INVATEC balloon was advanced into the diagonal branch beforehand and made sure that the proximal portion of the balloon protrudes into the LAD at a distance of 1–2 mm. A 3.5 ∗ 21 mm sirolimus-eluting stent was implanted in LAD and released with a minimum named pressure (8 atm) for 2 s. No residual stenosis in LAD and no occlusion of the diagonal branch were found (Fig. 1). Patient improved, with no chest pain now. 1. DiscussionThe branch balloon submerged embedding technique has the following advantages over the traditional side branch wire protection. (1) It can prevent the ostium of the side branch from aggravation. The predialation or stent implantation in the main vessel makes the plaque shift or change the kind of the stenosis, which leads to the ostium of the side branch occlusion or severe stenosis. As a result, the blood flow supplied to the side branch is reduced. The fact that the outer diameter of the submerged embedded balloon is much longer than the guide wire can partly protect the plaque against moving to the ostium of the side branch. The emergence of the technique offers considerable promise for the prevention of severe stenosis or occlusion in the ostium of the side branch and reduces the possibility of the implementation of the main branch-side branch kissing balloon or the stent-angioplasty in the side branch. (2) Performing PTCA with the aid of the submerged embedded balloon, we can restore the blood supply to the involved vessels, avoid artificial myocardial ischemia and myocardial necrosis, lower operation complications and decrease the pain that patients suffer. (3) It is favorable for exchanging the wires rapidly and reducing the difficulty of the balloon reentrance. The wire can find the ostium easily considering the fact that the dialationed side branch ostium has a long diameter and the resistance that the balloon comes into with is reduced significantly. As a result, the operation time and X-ray exposure time are both shortened and the contrast agent dosage is decreased. (4) The technique is simple to execute. The rate of protecting the wire and performing the operation is up to almost 100%. Branch balloon submerged embedding technique is an effective and safe measure to protect the SB during percutaneous coronary intervention (PCI) for bifurcation lesions.The difficult point of this technique is that it may get into trouble when removing the submerged embedded balloon. In our experience, the advance embedded balloon protrudes from the main branch slightly when the main branch predialation and stent implantation and the main branch are released with a minimum named pressure (6–8 atm). The balloon is opened up for a short while at a low pressure (4 atm) at where we come into resistance when removing comes into difficulty so as to create a fissure in the stent steel. The removed submerged embedded balloon will go on when the balloon is at negative pressure. The step will be repeated or the balloon pressure will be increased if the removed submerged embedded balloon is still not smooth. Deformation of the stent steel caused by the dilation of the submerged embedded balloon will be repaired by the postdialation of the balloon.A large collection of clinical practice experience shows that traditional wire protection technique can neither prevent the closure of side branches secondary to the plaque displacement nor restore blood flow to the involved side branch ostium. The difficulty of wire exchange and balloon reentrance will increase while the side branch is badly narrow, leading to aggravate suffering and prolong the operation time. In contrast, the branch balloon submerged embedding technique can protect the ostium of the side branch by means of preventing plaque from shifting and restore blood flow inside the shortest time. The technique reduces the difficulty of wire exchange and the dosage of contrast agent, and shortens the time of wire exchange and X-ray exposure. It is associated with low possibility of operation complications. More importantly, it does not increase the operation difficulty. This is why we decide to promote the technique, which is effective, safe and simple to execute. The branch balloon submerged embedding technique has the following advantages over the traditional side branch wire protection. (1) It can prevent the ostium of the side branch from aggravation. The predialation or stent implantation in the main vessel makes the plaque shift or change the kind of the stenosis, which leads to the ostium of the side branch occlusion or severe stenosis. As a result, the blood flow supplied to the side branch is reduced. The fact that the outer diameter of the submerged embedded balloon is much longer than the guide wire can partly protect the plaque against moving to the ostium of the side branch. The emergence of the technique offers considerable promise for the prevention of severe stenosis or occlusion in the ostium of the side branch and reduces the possibility of the implementation of the main branch-side branch kissing balloon or the stent-angioplasty in the side branch. (2) Performing PTCA with the aid of the submerged embedded balloon, we can restore the blood supply to the involved vessels, avoid artificial myocardial ischemia and myocardial necrosis, lower operation complications and decrease the pain that patients suffer. (3) It is favorable for exchanging the wires rapidly and reducing the difficulty of the balloon reentrance. The wire can find the ostium easily considering the fact that the dialationed side branch ostium has a long diameter and the resistance that the balloon comes into with is reduced significantly. As a result, the operation time and X-ray exposure time are both shortened and the contrast agent dosage is decreased. (4) The technique is simple to execute. The rate of protecting the wire and performing the operation is up to almost 100%. Branch balloon submerged embedding technique is an effective and safe measure to protect the SB during percutaneous coronary intervention (PCI) for bifurcation lesions. The difficult point of this technique is that it may get into trouble when removing the submerged embedded balloon. In our experience, the advance embedded balloon protrudes from the main branch slightly when the main branch predialation and stent implantation and the main branch are released with a minimum named pressure (6–8 atm). The balloon is opened up for a short while at a low pressure (4 atm) at where we come into resistance when removing comes into difficulty so as to create a fissure in the stent steel. The removed submerged embedded balloon will go on when the balloon is at negative pressure. The step will be repeated or the balloon pressure will be increased if the removed submerged embedded balloon is still not smooth. Deformation of the stent steel caused by the dilation of the submerged embedded balloon will be repaired by the postdialation of the balloon. A large collection of clinical practice experience shows that traditional wire protection technique can neither prevent the closure of side branches secondary to the plaque displacement nor restore blood flow to the involved side branch ostium. The difficulty of wire exchange and balloon reentrance will increase while the side branch is badly narrow, leading to aggravate suffering and prolong the operation time. In contrast, the branch balloon submerged embedding technique can protect the ostium of the side branch by means of preventing plaque from shifting and restore blood flow inside the shortest time. The technique reduces the difficulty of wire exchange and the dosage of contrast agent, and shortens the time of wire exchange and X-ray exposure. It is associated with low possibility of operation complications. More importantly, it does not increase the operation difficulty. This is why we decide to promote the technique, which is effective, safe and simple to execute.
What problem does this paper attempt to address?