Comparison of a 10-Breaths-per-minute Versus a 2-Breaths-per-minute Strategy During Cardiopulmonary Resuscitation in a Porcine Model of Cardiac Arrest.
Keith G. Lurie,Demetris Yannopoulos,Scott H. McKnite,Margot L. Herman,Ahamed H. Dris,Vinay M. Nadkarni,Wanchun Tang,Andrea Gabrielli,Thomas A. Barnes,Anja K. Metzger
2008-01-01
Abstract:BACKGROUND: Hyperventilation during cardiopulmonary resuscitation (CPR) is harmful. METHODS: We tested the hypotheses that, during CPR, 2 breaths/min would result in higher cerebral perfusion pressure and brain-tissue oxygen tension than 10 breaths/min, and an impedance threshold device (known to increase circulation) would further enhance cerebral perfusion and brain-tissue oxygen tension, especially with 2 breaths/min. RESULTS: Female pigs (30.4 +/- 1.3 kg) anesthetized with propofol were subjected to 6 min of untreated ventricular fibrillation, followed by 5 min of CPR (100 compressions/min, compression depth of 25% of the anterior-posterior chest diameter), and ventilated with either 10 breaths/min or 2 breaths/min, while receiving 100% oxygen and a tidal volume of 12 mL/kg. Brain-tissue oxygen tension was measured with a probe in the parietal lobe. The impedance threshold device was then used during an 5 additional min of CPR. During CPR the mean t SD calculated coronary and cerebral perfusion pressures with 10 breaths/ min versus 2 breaths/min, respectively, were 17.6 +/- 9.3 mm Hg versus 14.3 +/- 6.5 mm Hg (p = 0.20) and 16.0 +/- 9.5 mm Hg versus 9.3 +/- 12.5 mm Hg (p = 0.25). Carotid artery blood flow, which was prospectively designated as the primary end point, was 65.0 +/- 49.6 mL/min in the 10-breaths/min group, versus 34.0 +/- 17.1 mL/min in the 2-breaths/min group (p = 0.037). Brain-tissue oxygen tension was 3.0 k 3.3 mm Hg in the 10-breaths/min group, versus 0.5 +/- 0.5 mm Hg in the 2-breaths/min group (p = 0.036). After 5 min of CPR there were no significant differences in arterial pH, P-O2, or P-CO2 between the groups. During CPR with the impedance threshold device, the mean carotid blood now and brain-tissue oxygen tension in the 10-breaths/min group and the 2-breaths/min group, respectively, were 102.5 +/- 67.9 mm Hg versus 38.8 +/- 23.7 mm Hg (p = 0.006) and 4.5 6.0 mm Hg versus 0.7 +/- 0.7 mm Hg (p = 0.032). CONCLUSIONS: Contrary to our initial hypothesis, during the first 5 min of CPR, 2 breaths/min resulted in significantly lower carotid blood flow and brain-tissue oxygen tension than did 10 breaths/min. Subsequent addition of an impedance threshold device significantly enhanced carotid flow and brain-tissue oxygen tension, especially in the 10-breaths/min group.