Simultaneous Detection of Mercury, Lead and Strontium Ions Based on Conformational Conversion Sensor
Zhou Yuting,Tang Yujiao,Shao Shuang,Dai Shiyan,Cheng Guifang,He Pingang,Fang Yuzhi
DOI: https://doi.org/10.7503/cjcu20180868
2019-01-01
Abstract:A high. sensitive and specific electrochemical biosensor was designed for simultaneous detection of mercury ion(Hg2+), lead ion(Pb2+) and strontium ion(Sr2+) by oligonucleotide conformational transformation. The biosensor was based on porous anodic alumina(PAA) modified with two oligonucleotide aptamers which could capture Hg2+, Pb2+ and Sr2+, respectively. The aptamers can block [Fe(CN)(6)](3-/4-) ion conduction in the nanochannels of PAA. In the presence of Hg2+, Pb2+ and Sr2+, the aptamers could bend and wrap around those metal ions to make the nanochannel unobstructed, and then, the redox current of [Fe(CN)(6)](3-/4-) could be increased. When the biosensor eluted with beta-mercaptoethanol(beta ME), 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid(DOTA) and kryptofix 222(KP) successively, the aptamers stretched and released Hg2+, Pb2+ and Sr2+ in sequence, leading to the re-blockage of nanochannel with the decrease of the redox current. The calibration curves of Hg2+, Pb2+ and Sr2+ were obtained in the range of 0.05-2.50 nmol/L, and the detection limits were 0.013, 0.017 and 0.022 nmol/L, respectively. Further. more, the biosensor is easily constructed, stable and reusable. It is hopeful to apply in the daily monitoring of harmful metal ions in drinking water or environmental water.