[The Clinical Features of Gastrointestinal Bleeding Complicating Aortic Stenosis].

Fang Liu,Cheng-gong Jiang,Xue-ru Feng,Mei-lin Liu
DOI: https://doi.org/10.3760/cma.j.issn.0578-1426.2013.09.011
2013-01-01
Abstract:OBJECTIVE:To deepen the understanding about Heyde's syndrome by investigating the clinical characteristics and prognosis of the patients with aortic valve stenosis complicating with gastrointestinal bleeding.METHODS:Patients with aortic valve stenosis and gastrointestinal bleeding coincidently admitted to our hospital from 2001 to 2011 were retrieved and analyzed.RESULTS:In all the 443 157 in-patients, 474 patients were diagnosed with aortic valve stenosis (0.11%, 474/443 157) and 14 patients (9 males and 5 females, aged 53-87 years old) with gastrointestinal bleeding coincidently(2.95%, 14/474). Among the 14 patients, 3 were moderate aortic valve stenosis, 11 severe aortic valve stenosis. The aortic valve peak flow velocity was 324-709 (480.54 ± 188.25) cm/s and the mean aortic valve pressure gradient was 21.04-91.56 (56.93 ± 29.90) mm Hg(1 mm Hg = 0.133 kPa).Heavy gastrointestinal bleeding was manifested in all the 14 patients with 1 of haematemesis and 13 of hematochezia.Hemoglobin (Hb) and red blood cell (RBC) count were significantly lower than the normal range [(69 ± 28) g/L and (2.71 ± 2.04)×10(12)/L, P < 0.05]. Their mean corpuscular volume(MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), platelet(PLT) count, prothrombin time (PT) and international normalized ratio (INR) were in normal range [(90.21 ± 2.94) fl, (29.39 ± 1.99) pg, (327.57 ± 14.82) g/L, (185.13 ± 22.55)×10(9)/L, (11.4 ± 1.04) s and 1.22 ± 0.44, respectively]. Among all the 14 patients, 13 were over 65 years old and they all accepted gastrointestinal imaging (13/14).Vascular malformation of intestine was found in 6 patients with 4 lesions located in descending colon and 2 located in sigmoid colon.Hemorrhage foci were found in 2 patients with one of colon cancer, and another of duodenal ulcer, while no definite hemorrhage foci were found in the other 11 patients. A total of 6 patients with severe aortic valve stenosis underwent aortic valve replacement (AVR) successfully (6/11) and no recurrent gastrointestinal bleeding was ever found. Conservative treatment was performed in the other 5 patients with severe aortic valve stenosis (5/11) and resulted in sudden death in 2 patients (2/5).CONCLUSIONS:Prompt echocardiography and gastrointestinal endoscopy should be performed in the elderly patients with obscure gastrointestinal bleeding to facilitate the early diagnosis and treatment of Heyde's syndrome. AVR is a fundamental procedure to improve the prognosis of Heyde's syndrome.
What problem does this paper attempt to address?