Transcatheter Closure of a Giant Coronary Artery Fistula with Patent Duct Occluder
T Zhou,XQ Shen,ZF Fang,SH Zhou,SS Qi,XL Lu
DOI: https://doi.org/10.1097/00029330-200605010-00014
2006-01-01
Abstract:Coronary artery fistula (CAF), an uncommon form of congenital heart disease, is characterized by abnormal communication between a coronary artery and a cardiac chamber or vessel.1 This disease is often found incidentally in asymptomatic individuals, and leads to cardiac failure, myocardial ischemia and angina, infective endocarditis, and heart rupture in later life. Both surgical repair and transcatheter closure were effective and safe in the treatment of CAF,2 but percutaneous management of CAF can obviate median sternotomy and cardiopulmonary bypass, and there may be less morbidity with transcatheter embolization techniques,3,4 including the use of occluders or microcoils. We report a successful percutaneous closure of a giant CAF from the left coronary artery to the right ventricle using patent duct occluder. CASE REPORT A 24-year-old woman, who complained of palpitation and fatigue on exertion for five years, was admitted to our hospital in October 2005. Physical examination revealed a continuous murmur which was loudest in the third left intercostal space and a loud P2 was heard in the pulmonary area. The chest X-ray showed mild cardiomegaly and enlarged left ventricle was found in the ECG. On two-dimensional echocardiography, the right atrium (RA), right ventricle (RV), and left ventricle (LV) were enlarged. Dopper echocar- diography showed a continuous flow from the left coronary artery into RV. Cardiac catheterization, aortogram and selective coronary angiograms were performed under local anesthesia. The oxygen saturation of the right atrium and right ventricular were measured as 74% and 86%, which suggested a significant left-to-right shunt in RV. The pulmonary artery pressure was 45/18 mmHg and the pulmonary/systemic blood flow ratio was 1.6:1.0. Both aortogram and selective left coronary angiogram showed a giant CAF, whose diameter was near the aorta, from the left coronary artery to RV (Figs. 1 and 2) and a narrow neck was found in the distal segment. Multiple tiny CAFs were found in selective right coronary angiogram.Fig. 1.: Aortogram shows a giant CAF, which diameter is near of the aorta.Fig. 2.: Selective left coronary angiogram shows a markedly dilated left coronary artery with the fistula connected to the RV.Because of the patient's symptoms, significant shunt and large size of the fistula, we decided to close it by using transcatheter method. After one month, the procedure was carried out. The bilateral femoral artery and right femoral vein were punctured and 6F arterial sheath and 7F venous sheath were inserted. The left coronary artery was engaged with a 7F JL3.5 coronary angioplasty-guiding catheter (Cordis, USA); a 260 mm hydrophilic coated guidewire (TERUMO, Japan) and 5F 130 cm DAV catheter (Cook, USA) used to increase support were introduced through this catheter to the neck together; then the hydrophilic coated guidewire was controlled from RV into the pulmonary artery. A 6F pigtail catheter (Cordis, USA) was passed from right femoral vein, inferior vena cava, RA, RV to the pulmonary artery; the catheter was exchanged for Amplatzer “goose neck” snare (AGA Medical, USA) by 260 cm exchange wire (Cordis, USA); the hydrophilic coated guidewire was caught by in the pulmonary artery by the snare, and passed through the inferior vena cava, femoral vein, then the orbit was built. 9F delivery sheath (Lifetech Scientic Inc, China) failed to pass the narrow neck from venous system after trying many times, so we tried to use 8F delivery sheath (Lifetech Scientic Inc, China). Fortunately, the delivery sheath passed the neck. The position of the delivery sheath was confirmed by selective left coronary angiogram under multi-angle (Fig. 3). After careful aspiration and flushing, a 12/14 mm PDA occluder (Lifetech Scientic Inc, China) was advanced within the sheath until it passed the narrow neck of the CAF. The occluder was opened in the neck and the position of occluder was confirmed by left coronary artery angiography. The patient had no complaint and the ECG was similar to the preoperative during a 40-minute observation, and small residual shunting was found in the second angiography; so the occluder was deployed. Repeat angiography showed complete closure of the CAF, the stable shape of the device (Fig. 4), without residual shunting. The total time of operation was about 3 hours and the fluoro time was about 30 minutes.Fig. 3.: Selective left coronary angiogram confirms the position of the delivery sheath.Fig. 4.: Selective left coronary angiogram shows the stable shape of the device.DISCUSSION CAF is an uncommon anomaly, occurring as an incidental finding in 0.1% to 0.2% of coronary angiography.5 The fistula drainage site is of great significance, since it determines fistula flow rates, with fistula draining into the low-pressure right heart or pulmonary artery, theoretically, having the highest flow rates. The majority of fistulae drain into the right heart,6 with 15% draining into the pulmonary artery and 7% into the coronary sinus. Congenital arteriosystemic fistulae rarely drain into the left heart and, when present, are usually iatrogenically produced as a result of a surgical or percutaneous coronary intervention. Early closure is mandatory to prevent complications such as refractory congestive heart failure, myocardial ischemic or endocarditis for the rate of spontaneous closure of CAF is very low.7 Transcatheter closure of CAF with coils, polyvinyl alcohol particles or Amplatzer ductu occluder is a serious alternative for surgical treatment with excellent success and few complications. However, it is a very complicated and difficult procedure. In China, only some of the experienced surgeons have fulfilled successfully transcatheter closure of CAF.8–10 Five cases of CAF were accomplished by this technique11,12 and more than 4000 cases of coronary artery angiography were performed in our center, but it is the first time that we encountered such a large CAF. The report of trancatheter closure of such large CAF is rare. It is very difficult that guidewire and catheter go distally through the thin-walled coronary artery turnings and get permanently fixed in the location where occlusion is considered in giant CAF. There exist risks of coronary artery perforation and embolization of normal coronary artery. The 5F DAV catheter gave enough support in order to let hydrophilic-coated guidewire to the destination; at the same time, it would decrease the risk of complications. Although the CAF is very large, no big branch was found in the distal and there was a narrow neck in the distal of the CAF. So we chose transcatheter techniques. There was a small branch diverged from the distal of the CAF in preprocedure, but we could not confirm the place where the branch was connected. After the occluder opened in the neck, the branch disappeared in the selective coronary artery angiography. But in 40 minutes, no myocardial ischemia was suspected in the ECG and no complaint was made, so we deployed the device. We did not handle the CAF in the right coronary artery because it was too tiny. The success of this case demonstrates that transcatheter closure is feasible, effective, and safe for giant CAF as long as the condition is suitable for closure. But its long-term outcome needs to be investigated.