Measurement of 2∕1 intrinsic error field of Joint TEXT tokamak.

B Rao,Y H Ding,K X Yu,W Jin,Q M Hu,B Yi,J Y Nan,N C Wang,M Zhang,G Zhuang
DOI: https://doi.org/10.1063/1.4801461
IF: 1.6
2013-01-01
Review of Scientific Instruments
Abstract:The amplitude and spatial phase of the intrinsic error field of Joint TEXT (J-TEXT) tokamak were measured by scanning the spatial phase of an externally exerted resonant magnetic perturbation and fitting the mode locking thresholds. For a typical plasma with current of 180 kA, the amplitude of the 2/1 component of the error field at the plasma edge is measured to be 0.31 G, which is about 1.8x10(-5) relative to the base toroidal field. The measured spatial phase is about 317 degrees in the specified coordinate system (r, theta, phi) of J-TEXT tokamak. An analytical model based on the dynamics of rotating island is developed to verify the measured phase. (C) 2013 AIP Publishing LLC. [http://dx.doi.org/10.1063/1.4801461]
What problem does this paper attempt to address?