Multi-Shot Analysis of the Gamma Reaction History Diagnostic

D. B. Sayre,L. A. Bernstein,J. A. Church,H. W. Herrmann,W. Stoeffl
DOI: https://doi.org/10.1063/1.4729492
2012-01-01
Abstract:The gamma reaction history diagnostic at the National Ignition Facility has the capability to determine a number of important performance metrics for cryogenic deuterium-tritium implosions: the fusion burn width, bang time and yield, as well as the areal density of the compressed ablator. Extracting those values from the measured γ rays of an implosion, requires accounting for a γ-ray background in addition to the impulse response function of the instrument. To address these complications, we have constructed a model of the γ-ray signal, and are developing a simultaneous multi-shot fitting routine to constrain its parameter space.
What problem does this paper attempt to address?