Flame Temperature Measurements by Radar Resonance-Enhanced Multiphoton Ionization of Molecular Oxygen

Yue Wu,Jordan Sawyer,Zhili Zhang,Steven F. Adams
DOI: https://doi.org/10.1364/ao.51.006864
IF: 1.9
2012-01-01
Applied Optics
Abstract:Here we report nonintrusive local rotational temperature measurements of molecular oxygen, based on coherent microwave scattering (radar) from resonance-enhanced multiphoton ionization (REMPI) in room air and hydrogen/air flames. Analyses of the rotational line strengths of the two-photon molecular oxygen C-3 Pi(v = 2) <- X-3 Sigma(v' = 0) transition have been used to determine the hyperfine rotational state distribution of the ground X-3 Sigma(v' = 0) state. Rotationally resolved 2 + 1 REMPI spectra of the molecular oxygen C-3 Pi(v = 2) <- X-3 Sigma(v' = 0) transition at different temperatures were obtained experimentally by radar REMPI. Rotational temperatures have been determined from the resulting Boltzmann plots. The measurements in general had an accuracy of similar to +/- 60 K in the hydrogen/air flames at various equivalence ratios. Discussions about the decreased accuracy for the temperature measurement at elevated temperatures have been presented. (C) 2012 Optical Society of America
What problem does this paper attempt to address?