Measurements of the T(t,2n)4He Neutron Spectrum at Low Reactant Energies from Inertial Confinement Implosions.

D. T. Casey,J. A. Frenje,M. Gatu Johnson,M. J. -E. Manuel,N. Sinenian,A. B. Zylstra,F. H. Seguin,C. K. Li,R. D. Petrasso,V. Yu Glebov,P. B. Radha,D. D. Meyerhofer,T. C. Sangster,D. P. McNabb,P. A. Amendt,R. N. Boyd,S. P. Hatchett,S. Quaglioni,J. R. Rygg,I. J. Thompson,A. D. Bacher,H. W. Herrmann,Y. H. Kim
DOI: https://doi.org/10.1103/physrevlett.109.025003
2012-01-01
Abstract:Measurements of the neutron spectrum from the T(t,2n)4He (tt) reaction have been conducted using inertial confinement fusion implosions at the OMEGA laser facility. In these experiments, deuterium-tritium (DT) gas-filled capsules were imploded to study the tt reaction in thermonuclear plasmas at low reactant center-of-mass (c.m.) energies. In contrast to accelerator experiments at higher c.m. energies (above 100 keV), these results indicate a negligible n + 5He reaction channel at a c.m. energy of 23 keV.
What problem does this paper attempt to address?