[Performance of Internal-Loop Air-Lift Nitrifying Bioreactor].

Feng-Mei Lin,Ping Zheng,Yang-Yang Zhao,Bao-Lan Hu,Jian-Song Chen
DOI: https://doi.org/10.3321/j.issn:1000-3061.2002.04.019
2002-01-01
Abstract:The performance of internal-loop air-lift nitrifying bioreactor was good with strong tolerance to influent ammonia concentration (78.49 mmol/L), high volume converting rate (163.18 mmol/L.d) and obvious working stability (ammonia removal > 94.42%). During operation of internal-loop air-lift bioreactor, the nitrifying activated sludge was granulated. The nitrifying granular activated sludge began to appear on day 45. Its average diameter was 0.83 mm, settling velocity was 55.53 m/h and specific ammonia removal rate was 0.95 mmol (NH4(+)-N)/g (VS).d. The nitrifying granular activated sludge had the activity for anaerobic ammonia oxidation with ammonia oxidation rate of 0.23 mmol (NH4(+)-N)/g(VS).d and nitrite reduction rate of 0.24 mmol (NO2(-)-N)/g(VS).d.