Evaluation of a Series of Prolylamidepyridines As the Chiral Derivatization Reagents for Enantioseparation of Carboxylic Acids by LC–ESI–MS/MS and the Application to Human Saliva
Tomohiro Kuwabara,Takahiro Takayama,Kenichiro Todoroki,Koichi Inoue,Jun Zhe Min,Toshimasa Toyo’oka
DOI: https://doi.org/10.1007/s00216-014-7637-7
2014-01-01
Abstract:Mass spectrometry has become a popular analytical tool because of its high sensitivity and specificity. The use of a chiral derivatization reagent for the mass spectrometry (MS) detection seems to be efficient for the enantiomeric separation of racemates. However, the number of chiral reagents for the liquid chromatography (LC)–MS/MS analysis is very limited. According to these observations, we are currently in the process of developing novel labeling reagents for chiral molecules in MS/MS analysis. The derivatization reagent that is effective for enhancing not only the electrospray ionization–MS/MS sensitivity but also the reversed-phase LC resolution of carboxylic acid enantiomers should have a highly proton-affinitive moiety and an asymmetric structure near the reactive functional group. Furthermore, the resulting derivative has to provide a characteristic product ion suitable for the selected reaction monitoring. Based upon these considerations, a series of prolylamidepyridines ((S)-N-pyrrolidine-2-carboxylic acid N-(pyridine-2-yl)amide (PCP2), (S)-N-pyrrolidine-2-carboxylic acid N-(pyridine-3-yl)amide, and (S)-N-pyrrolidine-2-carboxylic acid N-(pyridine-4-yl)amide) was synthesized as ideal labeling reagents for the enantioseparation of chiral carboxylic acids and evaluated in terms of separation efficiency and detection sensitivity by ultra-performance LC (UPLC)–MS/MS. Among the synthesized reagents, PCP2 was the most efficient chiral derivatization reagent for the enantioseparation of carboxylic acid. The Rs values and the detection limits of the derivatives of non-steroidal anti-inflammatory drugs, which were selected as the representative carboxylic acids, were in the range of 2.52–6.07 and 49–260 amol, respectively. The sensitive detection of biological carboxylic acids (detection limits, 32–520 amol) was also carried out by the proposed method using PCP2 and UPLC–MS/MS. The PCP2 was applied to the determination of carboxylic acids in human saliva. Several biological carboxylic acids, such as lactic acid (LA), 3-hydroxybutylic acid, maric acid, succinic acid, α-ketoglutalic acid, and citric acid, were clearly identified in the saliva of healthy persons and diabetic patients. Furthermore, the ratio of d-LA in diabetic patients was higher than that in normal subjects. Judging from these results, PCP2 seems to be a useful chiral derivatization reagent for the determination not only of chiral, but also achiral, carboxylic acids in real samples.