Label-Free Detection of Radiation-Induced Apoptosis in Glioma Cells
C. Yang,D. Qi,W. Wang,P. Wang,X. Yang,Y. Sa,N. Zhang,Y. Feng
DOI: https://doi.org/10.1016/j.ijrobp.2015.07.1881
2015-01-01
Abstract:Purpose/Objective(s)Detection of radiation-induced apoptosis is commonly used in investigation of DNA-PK-deficiency and -proficiency of glioma cells. Current technologies use fluorescent stains which makes the same cell samples unusable for the protein expression studies. This study investigated the feasibility of detecting the cell apoptosis with a label-free method.Materials/MethodsHuman glioma cell line M059k was used. The cells were incubated at 37°C, 5% CO2and 80% humidity, and maintained as monolayer cultures in DMEM/F12 (1:1) medium supplemented with 10% fetal bovine serum, 1mM L-glutamine, 100 I.E./ml penicillin, 100 mg/ml streptomycin and 2.5 mg/ml fungisone. There were 2 groups of 6 samples, one for benchmarking the apoptotic rate and the other for measurement with the new method. Single fraction treatment of 8Gy was delivered with a 6MV beam. Apoptotic rates (Pa) of the cell samples at time points (tps) of 1h, 7h, 24h, 31h and 48h after treatment were first quantified by flow cytometry (FCM) assay under the standard Annexin V-FITC/PI assay protocol and used as reference for the comparison. Pa of the other group of the unstained cell samples was then quantified with a newly developed technique of polarization diffraction imaging flow cytometry (p-DIFC). 1000 images were acquired for each sample and a gray level co-occurrence matrix (GLCM) algorithm was used in morphological characterization of the apoptotic cells. 2 parameters were extracted and used in the quantification. The experiments were repeated 3 times and statistical analysis was performed with graphing software.ResultsPoster Viewing Abstracts 3306; Table 1R2 between GLCM parameters and Pa measured with FCM assayASM_SSumEnt_SPa by FCM0.940.98 Open table in a new tab ConclusionThe new method can effectively detect cell apoptosis. It makes it possible to use the same cell samples for investigation of the DNA-PK-deficiency and -proficiency of glioma cells. Purpose/Objective(s)Detection of radiation-induced apoptosis is commonly used in investigation of DNA-PK-deficiency and -proficiency of glioma cells. Current technologies use fluorescent stains which makes the same cell samples unusable for the protein expression studies. This study investigated the feasibility of detecting the cell apoptosis with a label-free method. Detection of radiation-induced apoptosis is commonly used in investigation of DNA-PK-deficiency and -proficiency of glioma cells. Current technologies use fluorescent stains which makes the same cell samples unusable for the protein expression studies. This study investigated the feasibility of detecting the cell apoptosis with a label-free method. Materials/MethodsHuman glioma cell line M059k was used. The cells were incubated at 37°C, 5% CO2and 80% humidity, and maintained as monolayer cultures in DMEM/F12 (1:1) medium supplemented with 10% fetal bovine serum, 1mM L-glutamine, 100 I.E./ml penicillin, 100 mg/ml streptomycin and 2.5 mg/ml fungisone. There were 2 groups of 6 samples, one for benchmarking the apoptotic rate and the other for measurement with the new method. Single fraction treatment of 8Gy was delivered with a 6MV beam. Apoptotic rates (Pa) of the cell samples at time points (tps) of 1h, 7h, 24h, 31h and 48h after treatment were first quantified by flow cytometry (FCM) assay under the standard Annexin V-FITC/PI assay protocol and used as reference for the comparison. Pa of the other group of the unstained cell samples was then quantified with a newly developed technique of polarization diffraction imaging flow cytometry (p-DIFC). 1000 images were acquired for each sample and a gray level co-occurrence matrix (GLCM) algorithm was used in morphological characterization of the apoptotic cells. 2 parameters were extracted and used in the quantification. The experiments were repeated 3 times and statistical analysis was performed with graphing software. Human glioma cell line M059k was used. The cells were incubated at 37°C, 5% CO2and 80% humidity, and maintained as monolayer cultures in DMEM/F12 (1:1) medium supplemented with 10% fetal bovine serum, 1mM L-glutamine, 100 I.E./ml penicillin, 100 mg/ml streptomycin and 2.5 mg/ml fungisone. There were 2 groups of 6 samples, one for benchmarking the apoptotic rate and the other for measurement with the new method. Single fraction treatment of 8Gy was delivered with a 6MV beam. Apoptotic rates (Pa) of the cell samples at time points (tps) of 1h, 7h, 24h, 31h and 48h after treatment were first quantified by flow cytometry (FCM) assay under the standard Annexin V-FITC/PI assay protocol and used as reference for the comparison. Pa of the other group of the unstained cell samples was then quantified with a newly developed technique of polarization diffraction imaging flow cytometry (p-DIFC). 1000 images were acquired for each sample and a gray level co-occurrence matrix (GLCM) algorithm was used in morphological characterization of the apoptotic cells. 2 parameters were extracted and used in the quantification. The experiments were repeated 3 times and statistical analysis was performed with graphing software. ResultsPoster Viewing Abstracts 3306; Table 1R2 between GLCM parameters and Pa measured with FCM assayASM_SSumEnt_SPa by FCM0.940.98 Open table in a new tab ConclusionThe new method can effectively detect cell apoptosis. It makes it possible to use the same cell samples for investigation of the DNA-PK-deficiency and -proficiency of glioma cells. The new method can effectively detect cell apoptosis. It makes it possible to use the same cell samples for investigation of the DNA-PK-deficiency and -proficiency of glioma cells.