Detection of target ssDNA using a microfabricated Hall magnetometer with correlated optical readout.

Steven M Hira,Khaled Aledealat,Kan-Sheng Chen,Mark Field,Gerard J Sullivan,P Bryant Chase,Peng Xiong,Stephan von Molnár,Geoffrey F Strouse
DOI: https://doi.org/10.1155/2012/492730
2012-01-01
Journal of Biomedicine and Biotechnology
Abstract:Sensing biological agents at the genomic level, while enhancing the response time for biodetection over commonly used, optics-based techniques such as nucleic acid microarrays or enzyme-linked immunosorbent assays (ELISAs), is an important criterion for new biosensors. Here, we describe the successful detection of a 35-base, single-strand nucleic acid target by Hall-based magnetic transduction as a mimic for pathogenic DNA target detection. The detection platform has low background, large signal amplification following target binding and can discriminate a single, 350 nm superparamagnetic bead labeled with DNA. Detection of the target sequence was demonstrated at 364 pM (<2 target DNA strands per bead) target DNA in the presence of 36 mu M nontarget (noncomplementary) DNA (<10 ppm target DNA) using optical microscopy detection on a GaAs Hall mimic. The use of Hall magnetometers as magnetic transduction biosensors holds promise for multiplexing applications that can greatly improve point-of-care (POC) diagnostics and subsequent medical care.