Micromechanical Measurement of Achbp Binding for Label-Free Drug Discovery

Koutilya Buchapudi,Xiaohe Xu,Yeganeh Ataian,Hai-Feng Ji,Marvin Schulte
DOI: https://doi.org/10.1039/c1an15734e
2012-01-01
Abstract:A potential binding assay based on binding-driven micromechanical motion is described. Acetylcholine binding protein (AChBP) was used to modify a microcantilever. The modified microcantilever was found to bend on application of the naturally occurring agonist (acetylcholine) or the antagonist (nicotine and d-tubocurarine). Control experiments show that microcantilevers modified without AChBP do not respond to acetylcholine, nicotine, and d-tubocurarine. K-d values obtained for acetylcholine, nicotine, and d-tubocurarine are similar to those obtained from radio-ligand binding assays. These results suggest that the microcantilever system has potential for use in label free, drug screening applications.