Robot-assisted stereotactic brain biopsy: A systematic review and meta-analysis
Silvio Porto Junior,Davi Amorim Meira,Beatriz Lopes Bernardo da Cunha,Jefferson Heber Marques Fontes,Hugo Nunes Pustilnik,Gabriel Souza Medrado Nunes,Gabriel Araújo Cerqueira,Maria Eduarda Messias Vassoler,Philippe Quadros Monteiro,Matheus Gomes da Silva da Paz,Tancredo Alcântara,Jules Carlos Dourado,Leonardo Miranda de Avellar
DOI: https://doi.org/10.1007/s10143-024-03122-4
IF: 2.8
2024-12-06
Neurosurgical Review
Abstract:Introduction: Intracranial lesions often require tissue diagnosis through stereotactic biopsies. Originating in the 1970s, this technique has progressed, but limitations and risks persist. Recently, robot-assisted techniques have made strides, providing the potential for safer and more precise procedures. This study assesses the effectiveness and safety of robot-assisted brain biopsies. Methods: Following Cochrane and PRISMA guidelines, PubMed, Embase, and Web of Science were searched for publications up to July 2024. Outcomes assessed included neurological deficits, hemorrhage, mortality, target point error, operative time, and length of stay. Data extraction and bias assessment were conducted using standardized methods, and statistical analysis was performed using R software. Results: In this meta-analysis, 27 papers were included, involving 2605 patients. The gender distribution was 1448 males to 1141 females. The mean error in millimeters for the entry point error was 1.04 (95%CI: 0.72–1.37), while the target point error was 1.08 (95%CI: 0.49–1.66). The mean operative time was 52.45 min (95%CI: 37.83–67.07). Diagnostic yield had an estimated rate of 98% (95%CI: 97–98%; I2=31%). The length of hospital stay was 4.64 days (95%CI: 3.13, 6.14), from admission to discharge. The postoperative hemorrhage had an estimated risk of 6% (95%CI: 4–9%; I2=71%), while for transient neurological deficits, it was 4% (95%CI: 2–6%; I2=60%). Finally, the death related to the procedure was found to have an estimated risk of 0% (95%CI: 0–0%; I2=0%). Conclusion: Our study found that the diagnostic yield of stereotactic brain biopsy, especially with robotic assistance, has proven to be highly effective. Robot-assisted biopsies also seems to reduce operative times and demonstrate high precision with low entry point error and target point error. Additionally, complication rates appear to be relatively low, and the average hospital stay is favorably short, underscoring the advantages of robotic assistance in stereotactic brain biopsy procedures.
surgery,clinical neurology