Graphene Coated Micro-Channel Fiber Sensor Based on Localized Surface Plasmon Resonance
Jingao Zhang,Jinhui Yuan,Yuwei Qu,Shi Qiu,Chao Mei,Xian Zhou,Binbin Yan,Qiang Wu,Kuiru Wang,Xinzhu Sang,Chongxiu Yu
DOI: https://doi.org/10.1364/josab.482275
2023-01-01
Abstract:In this paper, a novel localized surface plasmon resonance (LSPR)-based micro-channel photonic crystal fiber (PCF) sensor is proposed. The LSPR-PCF sensor is designed with the three micro-channels, and the metal nanos-traps and graphene are coated onto the PCF as the sensing elements. To realize high refractive index (RI) sensitivity, the influence of different plasmon materials, structure parameters, and graphene layers on the sensing performance of the LSPR-PCF sensor is investigated. The maximum wavelength sensitivity and amplitude sensitivity of the opti-mized LSPR-PCF sensor are up to 45800 nm/RIU and 1818 RIU-1, respectively, when the RI changes from 1.35 to 1.42. Furthermore, the proposed LSPR-PCF sensor achieves the maximum figure of merit of 594.8, alone with a resolution of 2.18 x 10-6 RIU. Because of its simple structure and excellent sensing performance, the proposed LSPR-PCF sensor has potential applications in biochemistry and environmental science.(c) 2023 Optica Publishing Group