A novel fluorescent strategy based on double modifications of metal organic framework material CAU-10-NH2 for low background and high sensitivity determination of H2S

Wenpeng Gong,Li Zhang,Ying Yu,Bixia Lin,Yumin Wang,Manli Guo,Yujuan Cao
DOI: https://doi.org/10.1016/j.talanta.2021.122271
IF: 6.1
2021-07-01
Talanta
Abstract:<p>Hydrogen sulfide is typical metabolic marker and environmental pollutant which is worthwhile to determine. Herein, a low background and high sensitivity fluorescent strategy based on double modifications of metal organic framework material CAU-10-NH<sub>2</sub> is proposed for the determination of hydrogen sulfide. Firstly, a functional monomer 3,5-diaminobenzoic acid is employed to modify on the CAU-10-NH<sub>2</sub>, the product CAU-10-NH-dAba has strong fluorescent performance at 412 nm under an excitation wavelength of 320 nm. Subsequently, it is further modified by the azide group to form CAU-10-NH-dAba-N<sub>3</sub>. This azidation inhibits the fluorescent signal. However, in the presence of hydrogen sulfide, the azide group is specifically reduced to amidogen, and results in the recovery of the fluorescence. The CAU-10-NH-DABA-N<sub>3</sub> was characterized by solid state NMR, XPS, fluorescence, IR, XRD, SEM and specific surface area. After the optimization of <em>p</em>H value, temperature and interaction time, the detection results of hydrogen sulfide demonstrate the linear range of this strategy is from 20 to 140 nM with a detection limit of 1.51 nM, which is significantly better than that of the CAU-10-NH<sub>2</sub> merely modified by 3,5-dinitrobenzoic acid. Meanwhile, the satisfactory assay results of hydrogen sulfide in serum sample and Pearl river water suggest a potential application prospect of this strategy in clinical diagnosis and environment monitoring.</p>
chemistry, analytical
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to develop a fluorescence detection strategy with low background signal and high sensitivity for the determination of hydrogen sulfide (H₂S). Specifically, the paper proposes a dual - modification method based on the metal - organic framework material (MOF) CAU - 10 - NH₂, achieving this goal by introducing the functional monomer 3,5 - diaminobenzoic acid (dAba) and azide groups. This method can restore the fluorescence signal in the presence of H₂S, thereby achieving efficient detection of H₂S. ### Main research contents and methods: 1. **Material synthesis and characterization**: - **Synthesis of CAU - 10 - NH₂**: CAU - 10 - NH₂ was synthesized by the hydrothermal method. - **Preparation of CAU - 10 - NH - dAba**: CAU - 10 - NH₂ was first modified with 3,5 - diaminobenzoic acid (dAba) through the EDC/NHS activation reaction. - **Preparation of CAU - 10 - NH - dAba - N₃**: On the basis of CAU - 10 - NH - dAba, the azide group was further introduced by reacting with tert - butyl nitrite and azide. 2. **Fluorescence performance test**: - **Fluorescence spectrum analysis**: The fluorescence performance of materials at different modification stages was tested by a fluorescence spectrometer. - **Infrared spectrum analysis**: The introduction of the functional monomer and azide group was verified by Fourier transform infrared spectroscopy (FTIR). - **X - ray diffraction analysis**: The crystal structure of the material was analyzed by X - ray diffraction (XRD). - **Specific surface area test**: The specific surface area of the material was tested by the Brunauer - Emmett - Teller (BET) method. - **Scanning electron microscope and transmission electron microscope analysis**: The morphology and size of the material were observed by SEM and TEM. 3. **Performance evaluation**: - **Feasibility test**: The feasibility of the method was verified by fluorescence testing, and the change of the fluorescence signal in the presence of H₂S was observed. - **Optimization conditions**: The pH value, temperature and incubation time were optimized to determine the best detection conditions. - **Linear range and detection limit**: The linear range and detection limit of the method were determined by the standard curve method. 4. **Practical application test**: - **Serum sample detection**: Serum samples were separated by centrifugation, and the H₂S content was detected using the optimized conditions, and the recovery rate was tested. - **Pearl River water sample detection**: Pearl River water samples were collected, and the H₂S content was detected using the optimized conditions, and the recovery rate was tested. ### Main conclusions: - **Low background signal**: By introducing the azide group, the background fluorescence signal was effectively suppressed. - **High sensitivity**: In the presence of H₂S, the azide group was reduced to an amino group, and the fluorescence signal was restored, achieving high - sensitivity detection of H₂S. - **Wide linear range**: The linear range of the method is 20 - 140 nM, and the detection limit is 1.51 nM, which is significantly better than other methods. - **Good selectivity and stability**: The method has good selectivity for H₂S and shows a stable fluorescence response under different storage conditions. - **Practical application prospects**: In the detection of serum samples and Pearl River water samples, the method shows good accuracy and reliability, and has potential clinical diagnosis and environmental monitoring application prospects. In conclusion, this paper proposes a dual - modification fluorescence detection strategy based on the MOF material CAU - 10 - NH₂, which successfully realizes the low - background - signal and high - sensitivity detection of H₂S and has wide application potential.