Analysis of Ventilation Efficiency Indices Inside a Local Domain in an Urban Area Using Two Building Model - Part (II): Effect of Wind Direction
Mahmoud Bady,Shinsuke Kato,Takéo Takahashi,Hong Huang
DOI: https://doi.org/10.11188/seisankenkyu.59.254
2007-01-01
Abstract:As the problem of air pollution inside urban areas became of major concern due to the increased levels of pollutants inside and around urban cities, estimation and analysis of pollutants concentrations are considered very important regarding the air quality inside urban domains. In the same time, it is considered that the estimation of concentrations only is not sufficient to reflect a complete image about the air quality inside such domains. Beside concentrations, still there is a need to estimate the pollutant behavior inside the domain such as the pollutant staying time and the number of returns of the pollutant to the domain. These needs derive us to establish a new concept that can satisfy the above requirements. On the other hand, there is a concept of the ventilation efficiency (VE) of indoor environments, which indicates diffusion properties for ventilation inside indoor climates. Recently, it was thought that the VE indices of indoor environments are also effective in evaluating the air quality of domains located inside urban areas (Huang et al. 2005). There are many indices which describe the VE of a domain such as Purging Flow Rate (the effective air flow rate to purge air pollutants from a domain, PFR), Visitation Frequency (the number of times a pollutant enters a domain and passes through it), Staying Time (the time a pollutant takes from once coming, or being generated, into the domain until its leaving) and the Six Indices SVE1-6 (Kato et al. 2003). In the present study, PFR will be considered only. The pattern of wind flow in urban areas is strongly affecting the dispersion of air pollutants around buildings. There are many factors which influence the air flow, such as the geometry and arrangements of buildings, wind directions, and the upstream terrain conditions (Zhang et al. 2005). The ambient wind direction is one of the important parameters to be considered by planners and designers for wind environmental improvements. This paper discusses the effect of ambient wind directions on the flow characteristics and on the air quality (reflected by the PFR) inside a domain located within an urban street canyon. The first stage of this work was done experimentally in order to estimate the parameters of the flow field and also to check the consistency of the experimental results. Of course, 2-D study is the basic, but 3-D analysis was considered here since the goal of this paper is evaluate the effects of ambient wind directions. The experiments were carried out for five wind directions which are: 0°, 30°, 45°, 60° and 90°. In the second stage, the measured parameters were used in the CFD simulations to solve the flow field numerically. As the CFD simulation results showed a reasonable agreement with the experimental results, the calculated flow field was utilized to estimate PFR.