A Reliable, Ultrasound-Based Method for the Diagnosis of Discoid Lateral Meniscus
Shun-Jie Yang,Ming-Zhi Zhang,Jian Li,Yang Xue,Gang Chen
DOI: https://doi.org/10.1016/j.arthro.2020.09.034
2021-03-01
Abstract:<h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Purpose</h3><p>To explore the feasibility and validity of ultrasound in the diagnosis of discoid lateral meniscus (DLM) by comparing quantitatively the morphological difference between DLM and normal lateral meniscus.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Methods</h3><p>This study was designed to develop and validate the ultrasound diagnostic criterion for DLM. In the development stage (07/2018-06/2019), data from 180 subjects was used to derive the ultrasound diagnostic criterion, including 90 patients diagnosed as DLM by MRI (DLM group) and 90 matched controls diagnosed as normal lateral meniscus diagnosed by MRI (control group). 12 distinct parameters of meniscus thickness, width, 0.5*thickness/width, and angle were obtained through anterior, lateral and posterior views with the probe oriented perpendicular to the lateral tibiofemoral joint line. In the validation stage (07/2019-12/2019), data from 324 additional participants were used to validate the criterion derived from the development stage. Differences of the continuous variables and categorical variables between the two groups were analyzed by an independent t test and chi-square test, respectively. The diagnostic value of parameters was analyzed by the ROC curve.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Results</h3><p>In the development stage, significant differences were found in the above 12 parameters between the two groups (p<0.05 for all). Cut-off values of anterior meniscus angle, meniscus body angle, and posterior meniscus angle were 28.45°, 27.85° and 29.15°, respectively. The AUC, sensitivity and specificity of anterior meniscus angle (0.953, 95.6%, 91.1%), meniscus body angle (0.980, 95.6%, 95.6%) and posterior meniscus angle (0.942, 80.0%, 97.8%) were higher than other parameters. In the validation stage, the sensitivity, specificity and accuracy of anterior meniscus angle, meniscus body angle, and posterior meniscus angle in diagnosing DLM were as high as 91.3%, 88.6% and 89.2%; 94.2%, 93.3% and 93.5%; 76.8%, 95.7% and 91.7%.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Conclusion</h3><p>DLM can be reliably diagnosed by ultrasound measurements of anterior meniscus angle, meniscal body angle, and posterior meniscus angle.</p>
surgery,orthopedics,sport sciences