Simultaneous Determination of Endocrine Disrupting Compounds Bisphenol F and Bisphenol AF Using Carboxyl Functionalized Multi-Walled Carbon Nanotubes Modified Electrode.

Jichun Yang,Xin Wang,Danfeng Zhang,Lingling Wang,Qi Li,Lei Zhang
DOI: https://doi.org/10.1016/j.talanta.2014.06.056
IF: 6.1
2014-01-01
Talanta
Abstract:A novel, simple and selective electrochemical method was developed for simultaneous determination of bisphenol F (BPF) and bisphenol AF (BPAF) in aqueous media (phosphate buffer solution, pH 6.0) on carboxyl functionalized multi-walled carbon nanotubes modified glassy carbon electrode (MWCNT-COOH/GCE) using differential pulse voltammetry (DPV). In DPV, MWCNT-COOH/GCE could separate the oxidation peak potentials of BPF and BPAF present in the same solution though, at the bare GCE, the peak potentials were indistinguishable. The results showed that the electrochemical sensor exhibited excellent electrocatalytic activity towards the oxidation of the two analytes. The peak current in DPV of BPF and BPAF increased linearly with their concentration in the ranges of 0.6-1.6 mmol/L BPF and 0.6-1.6 mmol/L BPAF. The detection limits were 0.1243 mmol/L and 0.1742 mmol/L (S/N=3) correspondingly. The modified electrode was successfully used to simultaneously determine BPF and BPAF in real samples.
What problem does this paper attempt to address?