Efficient solid and solution state emissive reusable solvatochromic fluorophore for colorimetric and fluorometric detection of CN-

Atanu Maji,Amitav Biswas,Krishnendu Aich,Saswati Gharami,Biswajit Bera,Tapan Kumar Mondal
DOI: https://doi.org/10.1039/d3an01697h
2024-01-16
The Analyst
Abstract:A novel organic receptor CPI [(E)-3-(4-(9H-carbazol-9-yl)phenyl)-2-(1H-benzo[d]imidazol-2-yl)acrylonitrile] was rationally designed and successfully fabricated for selective and sole recognition of CN- ion over others competitive anions through an obvious chromogenic and ratiometric emission change in DMSO. The distinct and prominent color change upon addition of CN- can be attributed to the typical ICT process, which is induced due to the deprotonation of acidic-NH proton in imidazole moiety. The sensor displayed strong solvatochromic effect in commonly used organic solvents such as n-hexane, toluene, diethyl ether, DCM, THF, DMF and DMSO. The chemical structure of the sensor has been characterized by single crystal X-ray diffraction, 1HNMR, 13CNMR, IR and mass spectroscopy. Significantly, the probe can function as a fluorescence based sensor for the efficient detection of low-level water in organic solvents. The solid state emission properties of CPI was successfully applied to recognize cyanide in solid state platform with naked eye visualized distinct color change. The probe can be made reusable by adding TFA into the CN- treated probe solution. The detection limit of CPI towards CN- was determined to be 4.48 ×10-8 M. More importantly, the sensor is capable for detecting CN- in food samples and has been employed for wastewater treatment. Besides, the easy-to-prepare CPI-coated test strips provide a simple, reusable and easy-to-handy protocol for qualitative identification of CN- conveniently. Finally, density functional theory and time-dependent density functional theory were performed to verify the experimental outcomes theoretically. The probe can be made reusable by adding TFA into the CN- treated probe solution. The detection limit of CPI towards CN- was determined to be in the order of 10-8 M. More importantly, the sensor is capable for detecting CN- in food samples and has been employed for wastewater treatment. Besides, the easy-to-prepare CPI-coated test strips provide a simple, reusable and easy-to-handy protocol for qualitative identification of CN- conveniently. Finally, density functional theory and time-dependent density functional theory were performed to verify the experimental outcomes theoretically.
chemistry, analytical
What problem does this paper attempt to address?