Research on dynamic temperature measurement method based on transient forward and inverse heat transfer model

Zhang Hua,Zhao Wenzhu,Wang Guodong
DOI: https://doi.org/10.19650/j.cnki.cjsi.2011.11.016
2011-01-01
Abstract:Based on the heat transfer model and inverse algorithm, a dynamic temperature measurement method was proposed for reducing the dynamic measurement errors of temperature sensors with large thermal lag. This method is used to obtain the actual temperature of measured medium through solving optimization problems. Non-linear unsteady transient forward heat transfer models and finite element solution equations of the temperature sensor are presented. On the basis of experimental validation, the first-order sensitivity formula of transient heat transfer is derived, and the transient inverse heat transfer models are established. The actual temperature can be achieved as the boundary condition with the fast inverse algorithm. The proposed method was applied to a compound temperature sensor with internal and external two layers of sheath and complex heat transfer process. Experiment and simulation results all show that the maximum error between measurement value and forward simulation value is less than 5°C, the relative error between real measured temperature and inverse calculation result is within 1%, the thermal response time is reduced from 548 s to 106 s. Application results prove the accuracy and rapidity of the proposed method.
What problem does this paper attempt to address?