Climatic Strategies Of Indoor Thermal Environment For Residential Buildings In Yangtze River Region, China

Baizhan Li,Wei Yu,Meng Liu,Nan Li
DOI: https://doi.org/10.1177/1420326X10394495
2011-01-01
Indoor and Built Environment
Abstract:Yangtze River Valley is situated within the Hot Summer and Cold Winter zone, and residents in this region of China would require HVAC system to alleviate thermal comfort conditions, although this is tempered by the Design Code (DBJ50-071-2007) for energy efficiency. A 1-year survey of about 200 residential homes was carried out in eight cities covering the breadth of the region. The acceptable temperature range for the residents in this area was 16.3-28.1 degrees C and the thermal neutral temperature was found to be 27.6 degrees C in summers and 17.5 degrees C in winters. People in different area can vary in their adaptability and comfortableness. Therefore, there is a need to investigate the national comfort parameter introduced in the Code for Design of Heating and Ventilation and Air Conditioning (GB50019-2003). The results found that if air-conditioning system was set to 27.5 degrees C instead of 26 degrees C as required by GBJ19-87: Design Standard of Heating and Ventilation and Air Conditioning, a 16.5% saving of energy consumption could be achieved. The findings demonstrated the role of natural ventilation in the expansion of the thermal comfort zone for the residents, especially during the summer seasons. A climatic adaptability model has been established by this study to contribute to the passive climatic design strategies for a better economic and energy efficiency of buildings.
What problem does this paper attempt to address?