Which is the preferred revision technique for loosened iliac screw? A novel technique of boring cement injection from the outer cortical shell.

Bin-Sheng Yu,Zhan-Kun Yang,Ze-Min Li,Li-Wen Zeng,Li-Bing Wang,William Weijia Lu
DOI: https://doi.org/10.1097/BSD.0b013e318224e55a
2011-01-01
Journal of Spinal Disorders & Techniques
Abstract:Study Design: An in vitro biomechanical cadaver study. Objectives: To evaluate the pull-out strength after 5000 cyclic loading among 4 revision techniques for the loosened iliac screw using corticocancellous bone, longer screw, traditional cement augmentation, and boring cement augmentation. Summary of Background Data: Iliac screw loosening is still a clinical problem for lumbo-iliac fusion. Although many revision techniques using corticocancellous bone, larger screw, and polymethylmethacrylate (PMMA) augmentation were applied in repairing pedicle screw loosening, their biomechanical effects on the loosened iliac screw remain undetermined. Methods: Eight fresh human cadaver pelvises with the bone mineral density values ranging from 0.83 to 0.97 g/cm(2) were adopted in this study. After testing the primary screw of 7.5 mm diameter and 70 mm length, 4 revision techniques were sequentially established and tested on the same pelvis as follows: corticocancellous bone, longer screw with 100 mm length, traditional PMMA augmentation, and boring PMMA augmentation. The difference of the boring technique from traditional PMMA augmentation is that PMMA was injected into the screw tract through 3 boring holes of outer cortical shell without removing the screw. On an MTS machine, after 5000 cyclic compressive loading of -200 beta - 500 N to the screw head, axial maximum pull-out strengths of the 5 screws were measured and analyzed. Results: The pull-out strengths of the primary screw and 4 revised screws with corticocancellous bone, longer screw and traditional and boring PMMA augmentation were 1167 N, 361 N, 854 N, 1954 N, and 1820 N, respectively. Although longer screw method obtained significantly higher pull-out strength than corticocancellous bone (P < 0.05), the revised screws using these 2 techniques exhibited notably lower pull-out strength than the primary screw and 2 PMMA-augmented screws (P < 0.05). Either traditional or boring PMMA screw showed obviously higher pull-out strength than the primary screw (P < 0.05); however, no significant difference of pull-out strength was detected between the 2 PMMA screws (P > 0.05). Conclusions: Wadding corticocancellous bone and increasing screw length failed to provide sufficient anchoring strength for a loosened iliac screw; however, both traditional and boring PMMA-augmented techniques could effectively increase the fixation strength. On the basis of the viewpoint of minimal invasion, the boring PMMA augmentation may serve as a suitable salvage technique for iliac screw loosening.
What problem does this paper attempt to address?