Gender Difference of Body Heat Tolerance in High Thermal and Humid Industrial Building

吕石磊,高萍,朱能,王志伟
2011-01-01
Abstract:In order to study the differences of such physiological indexes as body heat endurance duration and heat endurance limit between male and female in high thermal and humid industrial building environment,a high temperature and hygrothermal environmental chamber was used to stimulate the high thermal and humid industrial building environment.The physiological indexes of test population with different gender were measured,and thus,the limit values of key physiological indexes such as heat endurance duration,nonnasality temperature,heart rate and dehydration rate of body samples with different gender were obtained.In addition,the differences between wet-bulb globe temperature(WBGT) values were also determined.The results indicate that the female exhibits stronger heat and humid endurance abilities than the male in high thermal and humid industrial building environment.When the body reaches the heat tolerance limit,the heat stress response of female body is stronger than that of male body.Within shorter time,the female shows better thermal adjustment ability than the male.In high thermal and humid industrial building environment,the dehydration rate of the female is obviously lower than that of the male.Moreover,the WBGT values subjected by female are higher than those subjected by male.With reaching the heat tolerance limit,the WBGT values subjected by experimental body samples exceed the WBGT limit values in ISO7243 health standard by 6 ℃ to 8 ℃.