Abstract:The exploding urban population multiplies the traffic pressure, so the subway becomes the public transportation means essential to metropolises. Abnormal conditions of subway operation attract more and morce attention. The paper applied CFD to establish a physical model, simulating the hot environment (i.e., illumination, auxiliary facilities, heat Emission of human bodies, etc) around the air-conditioned train in case of blocking conditions in the subway tunnel, and sought the numerical solutions to the blocking conditions of 3 types of tunnel's (i.e., circle, rectangle and U-shaped). Conclusions are drawn as follows: Ventilation lowers the temperature inside the tunnel obviously; Under the same conditions, the temperature in side the rectangle tunnel reaches the highest, and then follows the circle tunnel and lastly the U-shaped tunnel; Under the same ventilating speed, the temperature above the top of the vehicle depends on the height between the vehicle to Pand tunnel top; For the circle and U-shaped tunnels, normal air-conditioning operation needs a ventilating speed of at least 2 m/s whereas for the rectangle tunnels, the ventilating speed should be above 2 m/s.