Hydrodynamic behaviour of submerged aerated filters with different media

BiBo Hu,Chun Yang,Andrew D. Wheatley
2011-01-01
Abstract:The submerged aerated filter (SAF) is an attractive technology in wastewater treatment with good removal efficiency and small footprint. However, there is little known about the flow pattern of the reactor. Tracer experiments using lithium chloride are carried out to study the hydrodynamics of SAFs with different media. Retention time distribution (RTD), Morill index, dead zone index, plug flow index, and short-circuiting index of SAFs at different operational conditions are obtained. The plug flow index of SAF with wool (8), wool red and wool crosses is 0.14, 0.14 and 0.61, respectively. The SAF with Kaldnes has slightly more plug flow properties than the others. The lowest dead space appeared in the SAF with wool crosses, which shows the most extent of mixing pattern. Therefore, the type of media is important to affect the effective volume and hydrodynamic behaviour of reactors.
What problem does this paper attempt to address?