Experimental Study of Soft X-Ray Emission from Pd-Like Xe Pumped by Capillary Discharge
Y. Zhao,M. Xu,Y. Xie,L. Li,Sh. Jiang,H. Cui,Q. Wang
DOI: https://doi.org/10.1007/s10812-014-9962-1
2014-01-01
Journal of Applied Spectroscopy
Abstract:Under different pressures, the temporal evolution and spectra of soft X-ray emission from a capillary discharge xenon plasma were measured with an X-ray diode and spectrometer, respectively. Transition lines from Xe8+ to Xe11+ were clearly observed and showed up as small spikes in the temporal profile. Within the 5–20 nm wavelength region, the spectra originating from transitions in the Xe8+ to Xe11+ ion species were observed bet ween 9 and 19 Pa. Among these spectral lines, the 16.47 nm line arises from the transition between the 4d 95p 1 P 1 level and the ground level of Pd-like xenon (Xe8+). The 4d 95p 1 P 1 level is the lower level of the 41.8 nm laser transition of 4d 95d 1 S 0–4d 95p 1 P 1. However, lasing output at 41.8 nm was not observed. According to our analysis, in order to realize the 41.8 nm lasing output, it is necessary to increase the electron temperature and the abundance of Pd-like Xe ions in the capillary discharge plasma.