Simultaneous Analysis of Hydrochlorothiazide, Triamterene and Reserpine in Rat Plasma by High Performance Liquid Chromatography and Tandem Solid-Phase Extraction.

Hang Li,Junting He,Qin Liu,Zhaohui Huo,Si Liang,Yong Liang
DOI: https://doi.org/10.1002/jssc.201000754
IF: 3.614
2011-01-01
Journal of Separation Science
Abstract:A tandem solid-phase extraction method (SPE) of connecting two different cartridges (C(18) and MCX) in series was developed as the extraction procedure in this article, which provided better extraction yields (>86%) for all analytes and more appropriate sample purification from endogenous interference materials compared with a single cartridge. Analyte separation was achieved on a C(18) reversed-phase column at the wavelength of 265 nm by high-performance liquid chromatography (HPLC). The method was validated in terms of extraction yield, precision and accuracy. These assays gave mean accuracy values higher than 89% with RSD values that were always less than 3.8%. The method has been successfully applied to plasma samples from rats after oral administration of target compounds.
What problem does this paper attempt to address?