Heat Transfer Performance of Pool Boiling on Horizontal Surface Sintered with Copper Fiber Felt

Tao Wenquan
2011-01-01
Abstract:The pool boiling heat transfer performance on horizontal surface sintered with copper fiber felt was investigated with deionized water as working fluid at atmospheric pressure.The copper fiber felt,which has four kinds of porosity(0.6,0.7,0.8 and 0.9)for a given fiber diameter(50 μm and 160 μm),is proposed to provide artificial nucleate sites to improve the heat transfer performance of pool boiling.High speed camera was employed to record the evolution of the pool boiling process on the heating surface.For fiber felt with a given fiber diameter,it is observed that the bubble departing diameter decreased as the increasing of porosity.However,the boiling heat transfer coefficient of the copper fiber felt showed a different variation tendency as the changing of porosity.It is revealed that the influence of porosity on the heat transfer performance on fiber felt was determined by the nucleate site density and the equivalent pore diameter of the fiber felt.
What problem does this paper attempt to address?