Stiffness amplification of actuator and governing error analysis in active vibration isolation

Tao ZHANG,Hong-biao HUANG,Bin WANG,Tai-ying ZENG,Jia XU,Fang LIU,Fang-fang ZHAO,Jian-qiang ZHU
DOI: https://doi.org/10.3969/j.issn.1000-3835.2010.05.011
2010-01-01
Abstract:Stiffness amplification of actuator and governing error in active vibration isolation (AVI) were investigated. The stiffness of an actuator should match the stiffness of the external load, and it could be amplified by connecting the actuator with a small stiffness spring in series if the load was heavy or the stiffness of the actuator was low. The performance of an AVI system was analyzed when the governing error was evenly distributed. The results showed that in order to obtain the same performance of vibration isolation, improving the relative accuracy of the controller and increasing the stroke of the actuator are both needed when the stiffness of the actuator is amplified; the stiffness of the actuator is equivalent to its stroke and the relative accuracy of the controller, they are replaceable. The results provided a guidance to select controller and actuator in an even wider area of AVI design.
What problem does this paper attempt to address?