Hydration Characteristics of the Slag from the Electric Arc Melting Furnace of Hospital Waste Incineration Ash

刘汉桥,魏国侠,张曙光,张书庭,张于峰
DOI: https://doi.org/10.3969/j.issn.0493-2137.2010.04.011
2010-01-01
Abstract:The influence on the hydration characteristics of ordinary Portland cement(OPC) incorporated with slag was studied in order to investigate the feasibility of the slag from electric arc melting furnace of hospital waste incineration ash as a cement admixture.It is proved that since slag has the potential hydration activity,if ordinary Portland cement was blended with quantitative slag,Ca(OH)2 in cement pastes would be reduced,and C―S―H filling the pore in hydration product would be increased,so microstructure of SBC pastes would be improved.But,if the amount of slag was excessive,the cement clinker would be relatively less.The hydration activity of the slag was impossible to be completely activated,resulting in reduced strength of SBC.The compressive strength of SBC pastes with replacement of 10% at the early curing stages(7 d)was lower,however,it would be apparently higher at later curing stages(60 d),which would reach 103% of the OPC pastes.Therefore,the addition dosage of slag should be about 10% if the slag is used as a partial cement substitute.
What problem does this paper attempt to address?