[Computer-Assisted Versus Traditional Cobb Angle Measurement on Digital Radiograph in Scoliosis].

Chu Wang,Li-feng Lao,Wen-xin Niu,Ze-jun Xing,Gui-xing Qiu,Zhi-hong Wu
DOI: https://doi.org/10.3760/cma.j.issn.0376-2491.2010.19.002
2010-01-01
Abstract:OBJECTIVE:To assess Mimics as a new measurement method in Cobb angle in a comparison with traditional measurement and try to explore the advantages and disadvantages of the new method.METHODS:Twenty X-ray plates of scoliosis were chosen randomly. Two experienced physicians measured the Cobb angles via Mimics and traditional methods twice with an interval of 1 week. And statistical analyses of Cobb angle and difference between two measurements were carried out.RESULTS:The overall correlation was 0.986 for Mimics and traditional measurements. ANOVA demonstrated no significant difference between these two methods. A significant difference existed between the first and second values of Cobb angle in Mimics and traditional measurements. However the absolute difference was small.CONCLUSION:Mimics can be a new method for measuring the digital radiographs. And its precision is superior to that of the traditional measurement.