Detection of Ureaplasma Urealyticum Biovar by Taqman Fluorescence Quantitative PCR.

Zhu ChangTai,Ling Yang,Dong Chun-lei,Yinze Kong,Yongping Liu,Changsong Zhang,Hu ZhongYi
2010-01-01
Abstract:Objective To establish Taqman fluorescence quantitative PCR method for detecting ureaplasma urealyticum(UU) biovars.Methods Based on differences in MBA genes of UU,primers and probes which were designed.We optimized the concentration of primers and probes and test conditions,and assessed the sensitivity,specificity and reproducibility of the tests.Results Taqman fluorescence quantitative PCR buffer systems for biovar 1 were as follow:25 μL reaction systems contained 2.5 U Taq enzyme,the level of Mg2+was 2.5 mmol/L,each of the upstream and downstream primer was 0.1 pmol/L,Taqman probe was 0.2 pmol/L,the template DNA was 2 μL.Optimum buffer systems of biovar 2 were as follow:25 μL reaction system contained 2.5 U Taq enzymes,the level of Mg2+was 2.5 mmol/L,each of the upstream and downstream primers was 0.2 pmol/L,Taqman probe was 0.3 pmol/L,the template DNA was 2 μL.There were the PCR reaction conditions,step l:95 ℃,2 min;step 2:95 ℃,10 s;55 ℃(detection point of fluorescent signal),20 s,40 cycles.The linear range of the test ranges were from 1.0×102 copy/mL to 2.0×108 copy/mL.The sensitivity of detection reached 100-200 copy/mL,the specificity reached 100%,and CV value was 2.5%.Conclusion The new established Taqman fluorescent PCR method for detecting UU biovars,which has a wide linear dynamic range,a high sensitivity and specificity,and a good reproducibility,can be used to test quickly UU biovars.
What problem does this paper attempt to address?