Research and application of laminar cooling control system under non-constant speed rolling

Enyang Liu,Lianggui Peng,Dianhua Zhang,Huaxin Chen,FengXiang Wang,HongWei Guo,Guiling Yang,Zongliang Wu
2010-01-01
Abstract:Runout table cooling equipment and new laminar cooling automatic control system structure of a hot strip mill were introduced. Coiling Temperature Control (CTC) mathematic models such as air cooling model, laminar cooling model, leed back control model and self-learning model were detailed described. As strip speed in the cooling area always changes to increase or decrease, speed leed forward compensation must be considered in order to control the coiling temperature more preferable. Segment tracking and recalculation by speed compensation were introduced in this paper. Since online application ot the new CTC system, the laminar cooling system has been running stably and reliably with a high precision, and mechanical properties of hot rolled strips are improved significantly, which lays a foundation for users to develop new products.