Abstract:Cavitation has close relationship with pressure fluctuations in centrifugal pumps. It is also one of the main sources which enlarge vibration and noise. By means of mounting pressure transducers on suction chamber and volute casing, fluctuating pressure signals were obtained and recorded at various cavitating operating conditions, then the time and frequency domains of the signals were analyzed using the FFT method. The results show that in semi-spiral suction chamber, as the available NPSH continuously decreases, the frequency range effected by cavitation extends to lower frequency. And the magnitude of pressure fluctuation at rotating frequency sharply increases at first and then decreases afterwards. On volute casing, the magnitude of pressure fluctuation at rotating frequency has the same trend as that in suction chamber. The magnitude of pressure fluctuation at blade passage frequency has close relationship with the measuring location related to the volute tongue, and has been little affected by cavitation. While significant pressure fluctuation magnitude rise is observed at the frequency of 1/2 of blade passage frequency. However, the measuring location has significant effect.