In-situ Measurement of Atmospheric Carbon Tetrachloride(ccl4)at the Shangdianzi Global Atmosphere Watch Regional Station

Bo YAO,Lingxi ZHOU,Fang ZHANG,Lin XU,Kunpeng ZANG,Xiaochun ZHANG,Xiaoling ZHANG,Huaigang ZHOU,Fan DONG,Liyan ZHOU
DOI: https://doi.org/10.13671/j.hjkxxb.2010.12.010
2010-01-01
Abstract:A gas chromatography-electron capture detector(GC-ECD) system was established at the Shangdianzi GAW(Global Atmosphere Watch) regional station for in-situ measurement of atmospheric carbon tetrachloride mixing ratios.From April 2007 to March 2008,the background CCl4 mixing ratio was(89.4 ± 0.7) × 10-12 mol·mol-1,close to the northern hemisphere background level observed at the Mace Head and the Trinidad Head stations.The polluted CCl4 mixing ratio was(94.7 ± 5.1) × 10-12 primarily due to anthropogenic emission from various regions and air mass transport.There was no significant seasonal variability of the background CCl4data.However,the polluted data was much higher in summer than in winter,elevated up to 7.6 × 10-12.Good correlation was observed between the enhanced CCl4 and the enhanced CO mixing ratios.A CO tracer-ratio method was applied to estimate the CCl4 emission from China during the study period.The estimated CCl4 emission was 4.7 kt·a-1 using the CO tracer-ratio method,which was close to the literature result obtained by the bottom-up method.Uncertainty of the emission estimate comes mainly from the homologous source assumption and station representativeness.
What problem does this paper attempt to address?