Performance test and hysteresis model of MR dampers with full-length effective damping path

Yang DING,Lu ZHANG,Yu-fei YAO,Zhong-xian LI
DOI: https://doi.org/10.3969/j.issn.1004-4523.2010.01.006
2010-01-01
Abstract:Because of the coil enwinded on the piston, half length of the damping path can't perform as effective length, which decreases the maximum damping force of the MR damper. In order to overcome this disadvantage, 2 MR dampers with full-length effective damping path are fabricated and tested based on the preliminary work includes conceptual design and theoretical analysis. The magnetic flux densities of the damping path, the force-displacement curves of the damper and the force-velocity curves of the damper in states with different current inputs are obtained. The mechanical model of the MR damper with full-length effective damping path is built by parameter identification of improved Sigmoid model. The experiment results show that the new-style magnetic circuit can realize the full-length effective theory, and the magnetic flux densities of the damping path in states are consistent with magnetic finite element analysis results. Compared to the traditional shear-valve mode MR damper of the same size, the maximum output powers of the MR damper with full-length effective damping path are 100% increased at least, and the adjustable range of the output powers is 70% increased at least. The improved Sigmoid model is both simply and precise and can perform as the mechanical model of the MR dampers with full-length damping path effectively.
What problem does this paper attempt to address?