Study on hydrodynamic performance of centrifugal pump with open-type diffuser

WU Da-Zhuan,JIANG Qing-Lei,Peng Wu,LI Zhi-Feng,WANG Le-Qin
2010-01-01
Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics
Abstract:To study the hydrodynamic performance of centrifugal pump with open-type diffuser in a specific hydraulic system, the hydrodynamic performance and the flow field of an open-type centrifugal pump was tested, and the internal flow and hydraulic performance of the pump system was analyze by using computational fluid dynamics (CFD). The structure of the open-type centrifugal pump with rectangular pressure tank and the numerical simulation methods were introduced. The experiment results and numerical simulation results achieved better consistency. The results show that the flow structure in open-type pump is complicated and the hydraulic losses of the pressure tank flow is significant, and the efficiency is lower than the volute centrifugal pumps. The performance reduction is mainly caused by structural restrict of the diffuser chamber and pressure tank, and the key of the open-type pump performance improvement lies on the rational design of the diffuser and the discharge structures of pressure tank.
What problem does this paper attempt to address?