Exergy Analysis for Thermal Power System of A 600 MW Supercritical Power Unit

LIU Qiang,DUAN Yuanyuan
2010-01-01
Abstract:The matrix equation for exergy balance of regenerative system was derived,and the mathematical model for exergy analysis of thermal power system was presented.Exergy losses and exergy efficiencies of the main components of a domestic N600-24.2/566/566 power unit were calculated by this model.The results indicate that the exergy efficiencies of low pressure heaters are lower than those of high pressure heaters,the exergy destructions in low pressure heaters are also lower.The exergy efficiency of the steam turbine is higher than relative internal efficiency,the exergy efficiencies of the high pressure turbine,intermediate pressure turbine and low pressure turbine are 93.20%,96.18% and 89.61%,but the work of the low pressure turbine is the largest,so there is energy conservation potential for the low pressure turbine.The coefficient of exergy loss is found to be maximum in the boiler(49.47%) while much lower in condenser(1.232%).In addition,the calculated thermal efficiency of this power plant is 44.54% while the exergy efficiency of the power cycle is 43.52%.