Analysis On Ex-Vessel Steam Explosion In Cpr1000(+) Unit

Juanhua Zhang,Jiming Lin,Shishun Zhang
DOI: https://doi.org/10.1115/ICONE18-30340
2011-01-01
Abstract:Reactor Pit Flooding System (RPF) is adopted under the severe accidents situation in CPR1000(+) units. It can move the heat generated from the reactor core via external reactor vessel cooling (ERVC) to keep the integrity of RPV and achieve the in-vessel corium retention (IVR). But if IVR function of RPF is failed, there is Ex-Vessel Steam Explosion (EX-SE) risk. The Ex-Vessel Steam Explosion is analyzed by MC3D software which is for fuel and cooling interaction (FCI). The physical model of CPR1000(+) for Steam Explosion is built firstly and then the phenomenon of Ex-Vessel Steam Explosion under typical severe accident is analyzed. The conclusion of this study is that the impulse load of pressure on the cavity wall induced by steam explosion is about 310KPas similar to 440KPas. Referencing the structure capacity of AP600 containment, if the structural capacity of CPR1000(+) containment is equal to AP600, the impulse load of pressure is lower than it. So it could be preliminarily estimated that steam explosion will not threaten the integrality of CPR1000(+) containment.
What problem does this paper attempt to address?