Abstract:Langmuir probe and fast Fourier transformation (FFT) were used to study the stand wave resonance frequency spectrum features of the plasma electrostatic oscillation of the unbalanced magnetron sputtering. The width of the frequency band was 0~300kHz. The range of resonance eigenfrequency change of the probes 2cm and 10cm in front of the magnetron sputtering under the typical discharge condition was respectively 10~50kHz and 1~10kHz. The impacts of the coil current,pressure and the discharge power on the resonance eigenfrequency were studied. The two potential trap structures causing the stand wave resonance of the plasma electrostatic oscillation in the unbalanced magnetron sputtering were identified and the stand wave resonance mechanism was proposed to explain the characteristic frequency occurred. The electron temperature calculated by the stand wave resonance mechanism conformed to the experiment results.
What problem does this paper attempt to address?